wide band isolation transformer ? for rf, ds3/e3, boradband, bpl and ethernet magnetics which require supplementary or reinforced isolation ? construction complies with iec60950 isolation requirement ? rohs compliant product ? operating temp : 0c to 70c (extended temperature subject to request) product performance is limited to specified parameter. data is subject to change without prior notice. r3600-xx 1004jw mechanical schematic r3600 series elect rical specificat ion @ 25c part no turns pri ocl pri dcr insertion loss insertion loss insertion loss hipot schematic ratio (h) min ( w ) max db max db max db typ v rms r3600- pri : sec 5% 1-4 1-4 1mhz 100mhz 300mhz pri to sec 1 1:1 500 0.30 -0.5 -1.0 -2.6 4500 b 2 1ct:1ct 800 0.50 -0.5 -1.2 -3.5 3000 a 3 1:2 120 0.20 -0.8 -1.0 -1.5 4500 b 4 1:1:1 120 0.20 -0.8 -1.0 -1.5 4500 c 5 3 : 3 : 1 200 0.30 -0.5 -1.0 -3.0 3000 c 6 1:1.224 500 0.50 -0.8 -1.0 -3.0 3000 b schematic a schematic b schematic c 2570 w. 237th street, suite b tel: (310) 325-1043 www.mpsind.com torrance, ca 90505 fax: (310) 325-1044 sales@mpsind.com dimensions unless otherwise specified, all tolerances are: inch: .xx : 0.015 .xxx : 0.004 mm: x,x : 0,38 x,xx : 0,10 note: ? ocl measured @ 100khz, 0.1v rms at pin 1-4 (with 2-3 shorted) ? insertion loss measured with 100 w as input (primary) impedance between 1-4 and output (secondary) load with respective impedance ? 50 w and 75 w impedance data available upon request
|